PowerMax® 4.0 For rooftop applications and solar parks

Mechanical specifications

PowerMax® 4.0 Value
External dimensions 1587 x 664 mm²
Thickness 38 mm
Weight 17 kg
Cell type CIGS
Frame none
Front cover 3.2 mm tempered glass
Junction box protection class IP67
Dimensions of the junction boxes 60 x 60 x 11,5 mm³
Cable lengths (-plug/ +socket) 200 / 320 mm
Cable cross section 2.5 mm²
Connector type TPCB-4

Electrical specifications

PowerMax® 4.0 135 140 145 150
Nominal power Pnom* 135 W 140 W 145 W 150 W
Sorting -0/+5 W -0/+5 W -0/+5 W -0/+5 W
Module efficiency η 12.8% 13.3% 13.8% 14.2%
Aperture efficiency η 14.2% 14.7% 15.2% 15.7%
Open-circuit voltage Voc* 78.9 V 79.5 V 80.1 V 80.7 V
Short-circuit current Isc* 2.57 A 2.58 A 2.59 A 2.59 A
Voltage at mpp Vmpp* 59.7 V 60.8 V 61.9 V 63.0 V
Current at mpp Impp* 2.26 A 2.30 A 2.34 A 2.38 A
Max. over-current protection Ir 4.0 A 4.0 A 4.0 A 4.0 A
Max. system voltage Vsys 1000 V 1000 V 1000 V 1000 V

Insolation intensity 1000 W/m² in the plane of the module, module temperature 25 °C and a spectral distribution of the sunlight according to the atmospheric mass (AM) 1.5.

* Tolerance of Manufacturing: -5 %/+10 %.


Data measured at nominal module temperature (NOMT)** and AM 1.5:

PowerMax® 4.0 135 140 145 150
NMOT 40 °C 40 °C 40 °C 40 °C
Nominal power Pnom 101 W 105 W 109 W 113 W
Open-circuit voltage Voc 75 V 76 V 76 V 77 V
Short-circuit current Isc 2.06 A 2.06 A 2.07 A 2.07 A
Voltage at mpp Vmpp 56 V 57 V 58 V 59 V

** NMOT: Module operating temperature at 800 W/m² insolation intensity in the plane of the module, air temperature 20 °C, wind speed 1 m/s and open-circuit condition.


Temperature coefficients

PowerMax® 4.0 Value
Temperature coefficient Pnom -0.39%/°C
Temperature coefficient Voc -230 mV/°C
Temperature coeffizient Isc 0 mA/°C

Data measured at low light intensity:

The relative reduction in module efficiency at a light intensity of 200 W/m² relative to 1000 W/m² at 25 °C module temperature and spectrum AM 1.5 is 6%. At 500 W/m² the relative increase of the module efficiency is +1%.

More information on handling, installation and operation can be found in the installation, operation and safety handbook.

As a result of ongoing research and product improvements, the specifications in this product data sheet are subject to changes without prior publication. All information is accurate to the best of our knowledge however does not constitute an assurance for any specific product features and does not give rise to any legal relationship. Installation equipment is not supplied with the product.

 

Data valid for modules produced on/after January 1st, 2018.


Dimensions

PowerMax_40_Frontside
PowerMax_40_Frontside
PowerMax_40_Backside
PowerMax_40_Backside
PowerMax_40_Dimensions
PowerMax_40_Dimensions

Certificates

Downloads