PowerMax® 3.5 For rooftop applications and solar parks

Mechanical specifications

PowerMax® 3.5 Value
External dimensions 1587 x 664 mm²
Thickness 38 mm
Weight 17 kg
Cell type CIGS
Frame none
Front cover 3.2 mm tempered glass
Junction box protection class IP65
Dimensions of the junction boxes 70 x 64 x 13 mm³
Cable lengths (-plug/ +socket) 180 / 310 mm
Cable cross section 2.5 mm²
Connector type LC4

Electrical specifications

PowerMax® 3.5 130 135 140 145
Nominal power Pnom 130 W 135 W 140 W 145 W
Tolerance of nominal power ΔPnom -0/+4% -0/+4% -0/+4% -0/+4%
Module efficiency η* 12.3% 12.8% 13.3% 13.8%
Aperture efficiency η 13.6% 14.2% 14.7% 15.2%
Open-circuit voltage Voc 58.6 V 59.2 V 59.8 V 60.4 V
Short-circuit current Isc 3.35 A 3.35 A 3.36 A 3.36 A
Voltage at mpp Vmpp 43.7 V 44.9 V 46.1 V 47.4 V
Current at mpp Impp 2.98 A 3.01 A 3.04 A 3.06 A
Limiting reverse current Ir 5.0 A 5.0 A 5.0 A 5.0 A
Max. system voltage Vsys (IEC) 1000 V 1000 V 1000 V 1000 V
Max. system voltage Vsys (UL) 600 V 600 V 600 V 600 V

* Insolation intensity 1000 W/m² in the plane of the module, module temperature 25 °C and a spectral distribution of the sunlight according to the atmospheric mass (AM) 1.5.


Data measured at nominal operating cell temperature (NOCT)** and AM 1.5:

PowerMax® 3.5 130 135 140 145
NOCT 40 °C 40 °C 40 °C 40 °C
Nominal power Pnom 97 W 101 W 105 W 109 W
Open-circuit voltage Voc 55.6 V 56.2 V 56.8 V 57.4 V
Short-circuit current Isc 2.68 A 2.68 A 2.69 A 2.69 A
Voltage at mpp Vmpp 41.1 V 42.3 V 43.5 V 44.7 V

** NOCT: Module operating temperature at 800 W/m² insolation intensity in the plane of the module, air temperature 20 °C, wind speed 1 m/s and open-circuit condition.


Temperature coefficients

PowerMax® 3.5 Value
Temperature coefficient Pnom -0.39%/°C
Temperature coefficient Voc -170 mV/°C
Temperature coeffizient Isc 0 mA/°C

The relative reduction in module efficiency at a light intensity of 200 W/m² relative to 1000 W/m² at 25 °C module temperature and spectrum AM 1.5 is 6%. At 500 W/m² the relative increase of the module efficiency is +1%.

More information on handling, installation and operation can be found in the installation, operation and safety handbook.

The measurement accuracy of Pnom is ± 3.5 %. As a result of ongoing research and product improvements, the specifications in this product data sheet are subject to changes without prior publication. All information is accurate to the best of our knowledge however does not constitute an assurance for any specific product features and does not give rise to any legal relationship. Installation equipment is not supplied with the product.


Dimensions


Certificates

  • IEC 61646 1.00 M

    IEC 61646 Certificate, TÜV Rheinland, english version
  • IEC 61730 1.05 M

    IEC 61730 Certificate, TÜV Rheinland, english version
  • IEC 62716 1.07 M

    IEC 62716 Certificate, TÜV Rheinland, english version
  • IEC 61701 1.05 M

    IEC 61701 Certificate, TÜV Rheinland, english version